Skip to main content

Package Relevance Protocol


The following protocol details the package relevance scoring system.

[Relevance] % = [Total Points]/[Maximum Possible Points]

Facet must be selected to count towards relevance.

Relevance Color Codes:
Full Match (100%)
High Match (70% to <100%)
Partial Match (40% to <70%)
Low Match (>0% to <40%)
No Match (0%)
Facet Options Description Points
Zipcode Enter US zip code Matches packages with providers in the same state as zip code. 15
Installation and Assurance Toggle Required Packages including installation and assurance get full points 5
Customer Engagement Partner-Eligible Packaged Systems Toggle Required Customer Engagement Partner-Eligible Packaged Systems get full points 2
Size (kW) Enter target size (kW) and allowed range (%) Matches packages with size within range (entered size ±range%).
Package greater than 150% of size
Package less than 25% 0f size
10
-10
Prime Movers Select one or more:
  • Reciprocating engines
  • Combustion turbines
  • Microturbine
  • Fuel Cell

Packages that exactly match 1 of the selected get full points

5

Fuel Types Select one or more:
  • Natural Gas
  • Propane
  • Digester Gas
  • Landfill Gas

Packages that exactly match 1 of the selected get full points


Packages that do not match any of the selected

15


-10
Thermal Outputs Select one or more:
  • Hot Water Only
  • Chilled Water Only
  • Hot Water and Chilled Water
  • Hot Water and ORC
  • Steam Only
  • Steam and ORC
  • Steam and Hot Water
  • Steam and Chilled Water
  • Steam, Hot Water, and Chilled Water
  • Steam, Hot Water, Chilled Water, and ORC

Packages that exactly match 1 of the selected get full points


Packages that do not match any of the selected

10


-10

Grid Connection Type Select one or more:
  • Grid Parallel Only
  • Grid Island, Black Start, Manual Transfer
  • Grid Island, Black Start, Auto Transfer

Packages that exactly match 1 of the selected get full points

5

Packaged in America Toggle Required Packaged in America Systems get full points 2
Outdoor Installation Toggle Required Packages with Standard Outdoor Installation receive full points
Packages with Optional Outdoor Installation receive half points
10
Packaged System Footprint Set one or more:
  • Width
  • Length
  • Height

Packages that are within the selected footprint get full points.

Height is only compared with height.

If only length or width is selected, it is only compared against the shorter package length and width dimensions, unless ">50" is selected, which is compared against the longest length or width package dimension.

If both length and width are selected, The longest is compared to the longest package length or width dimension while the shorter of the 2 are compared.

2